Automation Displays, Inc.
Your Source for Graphic Control Panels
Home
Up

 

 

 

 

UL Model Series  = TAC / INV / AND

Schneider Electric  Request for Quote -  Firefighters Smoke Control Override Panel

Note:  ADI manufactures 3 separate UL864 -UUKL Listed model series for Schneider Electric.  All models are defined in the Automation Displays Inc. UL File S1793 Vol2 for Ul864-UUKL 9th Edition Smoke Control Panels.

Contact Information:

Your Name*  

Company*     

Address        

Address        

City                 State      Zip  

Telephone*       Fax      

Email *          

* required field

Project Identification:

             Name          

             Description  (i.e. 15 floor office bldg underground parking)
                                
           
              Location   (city, county, state)
                                    
 

Define Schneider Electric Building -  Automation System for your project: 

   AND-xxxxx model series is for the Continuum System

   INV-xxxxx model series is for  I/A Series, MicroNet BACnet System

   TAC-xxxxx model series is for the Xenta/Vista System

AND-XXXXX  =  Continuum system FSCS interface uses Net Controller modules: CX9900-S Series (CX9900-S and CX9940‑S).    Smoke Control panels with this interface will include the following UL required panel devices.   Panel Power LED, Lamp Test pushbutton, Panel Enable Key Switch (or Security Door), Audible Alarm, Alarm Silence Key Switch,  Comm. Fault LED and System Fault LED.

INV-XXXXX  = MicroNet BACnet FSCS  interface requires an MNB1000 Controller and uses  ModBus Protocol Interface.  Smoke Control panels with this interface will include the following UL required panel devices. Panel Power LED, Lamp Test pushbutton, Panel Enable Key Switch (or Security Door), Audible Alarm, Alarm Silence Key Switch and System Fault LED. Please provides MNB-1000 Controller and EMSC-541 Transformer.

TAC-XXXXX = Xenta and Vista system interfaces to the FSCS via the model "Xenta 913-U8" interface.  Smoke Control panels with this interface will include the following UL required panel devices.   Panel Power LED, Lamp Test pushbutton, Panel Enable Key Switch (or Security Door), Audible Alarm, Alarm Silence Pushbutton,  Reset Alarm or Faults Pushbutton,  Comms. Fault LED and Equipment Fault LED.

 
Define Panel Devices Required OR  Define Equipment Controlled for Smoke Control
Number of LEDS:    
Red   Yellow
Green   Blue
Amber   White
Number of Switches:
Maintained Toggle Switches
2 position   3 position
         
Rotary Switches (up to 12 positions available)
2 position   3 position
4 position   5 position
         
Maintained key switch (SPST)
2 position      
         
Number of Other Devices
Lamp Test Switch   Sonalert Audible Alarm
         
 
   
 

 

 
    Number of Fans
Note: include stairwell pressurization fans, exhaust fans, make up air fans, supply air fans, all fans in Air Handling Unit (AHU) used for Smoke Control
Number of Dampers
Note: include all fire smoke dampers, motorized dampers used for smoke control, all dampers in Air Handling Units (AHU) used for smoke control

Number of Doors/Windows   used for Make Up Air

 
Automation Displays, Inc. will estimate the number of panel devices required based on your equipment listed above and building code for your state or city.
 

Number of remote inputs from Fire Alarm System-  Fire Alarm system provides dry contact outputs so BMS can activate a smoke sequence.

 
 
Enclosure (select enclosure size and indicate quantity)
Size (select one)   Mounting Options (Select One)   Special Options (Select all that apply)
24"h x 18"w (in stock)            
24"h  x  24"w  (in stock)    Surface Mounted   Floor Pedestal (for large surface mount enclosures)
36"h  x  24"w  (in stock)    Flush Mounted   Locking Security Cover (with polycarbonate window)
24"h  x  36"w  (in stock)             

Custom size:            
  __"h x ___"w Note: ADI will define custom sizes based on project requirements
 
Smoke Control Manufacturing Specifications
The smoke control panel should be built to the following specification:
NFPA 92 Smoke Control Guideline International Building Code (IBC) Section 909 Other Local Building Code
I don't know        
Is UL Listing required?   (UL 864 UUKL Listing)  Yes     No
 
Note: Please send to ADI all written specifications and all drawings that are available for this project:
Drawings sent via:  
Email (option available after pressing submit button)
FEDEX, UPS, US Mail
No written Specifications
Written specifications  sent via:
Email (option available after pressing submit button)
FEDEX, UPS, US Mail
No written Specifications