Automation Displays, Inc.
Your Source for Graphic Control Panels
Home
Up

 

 

 

UL Model Series  = UFD

Siemens Industries, Inc.  Request for Quote 

 this quote is for an ADI Firefighter's Smoke Control Station used

with the Siemens Industries, Inc Apogee System

Contact Information:

Your Name*  

Company*     

Address        

Address        

City                 State      Zip  

Telephone*       Fax      

Email *          

* required field

Project Identification:

             Name          

             Description  (i.e. 15 floor office bldg underground parking)
                                
           
              Location   (city, county, state)
                                    
 

Serial Interface

The FSCS panel devices are wired to an ADI Z-card serial interface that communicated with the Siemens Industries, Inc.   PXC-Modular Controller.  ADI does not supply the PXC-Modular Controller units, but does supply the required din rail for mounting and the required transformer.  DO NOT SEND PXC-Modular Controller Units to ADI.

The Siemens Industries, Inc.  System also requires a PXX-485-3 unit that is used as a communication link from the control panel. DO NOT SEND the PXX-485-3 unit for this project to ADI.

All control panel switches and LEDs are wired to the ADI supplies Z-card serial interface circuit that will communicate with the PXC and the PXX-485-3 module using the FLN-1 connection.

Panels are constructed in accordance with Siemens Industries, Inc. UL File S4073, Vol 3 and will have Siemens Industries Inc UL Label affixed.

 

 
Define Panel Devices Required

             OR 

 Define Equipment Controlled for Smoke Control
Number of LEDS:    
Red   Yellow
Green   Blue
Amber   White
Number of Switches:
Maintained Toggle Switches
2 position   3 position
         
Rotary Switches (up to 12 positions available)
2 position   3 position
4 position   5 position
         
Maintained key switch (SPST)
2 position      
         
Number of Other Devices
Lamp Test Switch   Sonalert Audible Alarm
         
 
   
 

 

 
    Number of Fans
Note: include stairwell pressurization fans, exhaust fans, make up air fans, supply air fans, all fans in Air Handling Unit (AHU) used for Smoke Control
Number of Dampers
Note: include all fire smoke dampers, motorized dampers used for smoke control, all dampers in Air Handling Units (AHU) used for smoke control

Number of Doors/Windows   used for Make Up Air

 
Automation Displays, Inc. will estimate the number of panel devices required based on your equipment listed above and building code for your state or city.
 

Number of remote inputs from Fire Alarm System-  Fire Alarm system provides dry contact outputs so BMS can activate a smoke sequence.

 
 
Enclosure (select enclosure size and indicate quantity)
Size (select one)   Mounting Options (Select One)   Special Options (Select all that apply)
24"h x 18"w (in stock)            
24"h  x  24"w  (in stock)    Surface Mounted   Floor Pedestal (for large surface mount enclosures)
36"h  x  24"w  (in stock)    Flush Mounted   Locking Security Cover (with polycarbonate window)
24"h  x  36"w  (in stock)             

Custom size:            
  __"h x ___"w Note: ADI will define custom sizes based on project requirements
 
Smoke Control Manufacturing Specifications
The smoke control panel should be built to the following specification:
NFPA 92 Smoke Control Guideline International Building Code (IBC) Section 909 Other Local Building Code
I don't know        
Is UL Listing required?   (UL 864 UUKL Listing)  Yes     No
 
Note: Please send to ADI all written specifications and all drawings that are available for this project:
Drawings sent via:  
Email (option available after pressing submit button)
FEDEX, UPS, US Mail
No written Specifications
Written specifications  sent via:
Email (option available after pressing submit button)
FEDEX, UPS, US Mail
No written Specifications